Author: admin

  • Instruction Manual EBARA Submersible Semi-Vortex Sewage Pumps DVS

    Introduction Check the following points upon receipt of your pump:(1) Is the pump exactly what you ordered? Check the name­ plate. It is especially important that you check whether the pump is to be used with 50 Hz or 60 Hz.(2) Has any damage occurred during shipment? Are any bolts or nuts loose? (3) Have…

  • Instruction Manual EBARA End Suction Volute Pumps GS

    Installation 1. Location (1) This pump should be installed indoors (except for option pump of outdoor + motor of outdoor).(2) There should be ample space around the pump, and securing a large working space for maintenance and inspection.(3) Provide an enclosure around the pump, or take some other effective measures to prevent unauthorized personnel from…

  • INSTRUCTION MANUAL EBARA HORIZONTAL SPLIT CASING CENTRIFUGAL PUMP

    Model CSA & CNA Safety Information and Introduction WARNINGBefore handling this pump, always disconnect the power first. No open flame or use spark able electrical devices or flames in a septic (gaseous) or possible septic sump. Do not work under heavy Suspended object unless there is a positive support under it to stop its fall…

  • Regular Submersible Motor Inspections

    Daily Inspections (1) Check for excessive vibration and strange sounds.(2) Check working order(3) Check electric current values.Remarks Confirm that there are no sudden changes in current or pressure.Measure and record values regularly. Monthly Inspection (1) Measure insulation resistance.(2) Measure continuity. Check insulation resistance lower limits.Confirm U-V, V-W, W-U thermal protectors continuityConfirm that thermal protector coil…

  • INSTRUCTION MANUAL EBARA End Suction Volute Pump MODEL FSA

    Installation 1.LOCATION (1) This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install where inspection and maintenance can be easily performed.(3) Provide suitable enclosure to prevent entry of unauthorized persons.(4) Install pump as close to…

  • EBARA VERTICAL IN-LINE CENTRIFUGAL PUMP Instruction Manual

    Model LPDC 1.Installation location (1)This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install where inspection and maintenance can be easily performed. (3) Provide suitable enclosure to prevent entry of unauthorized persons.(4) Install pump as…

  • Regular Diesel Engine Inspections

    Daily Inspection (1) Inspect appearance.(2) Check for vibration and unusual sounds.(3) Check bearing temperature.(4) Check lubricating oil pressure.(5) Check lubricating oil level.(6) Drain air from tank.(7) Check exhaust gas color Monthly Inspection (1) Clean fuel filter.(2) Clean lubricating oil filter.(3) Oil all sliding parts.(4) If the unit has not been in use for an extended…

  • Understanding Pressure Drop in Valves: A Visual Guide

    PRESSURE DROP/FLOW RATE DIAGRAM – BALL VALVE PRESSURE DROP ΔP DIAGRAM – CHOKE VALVE ( Butterfly valve) PRESSURE DROP ΔP DIAGRAM – FOOT VALVE ( Bottom valve) PRESSURE DROP ΔP DIAGRAM – BRASS CHECK VALVE PRESSURE DROP ΔP DIAGRAM – FLANGED CHECK VALVE IN CAST IRON PRESSURE DROP IN EQUIVALENT LENGTH OF PIPE IN METRES…

  • Effects of Sudden Changes on Pipe Pressure

    DN = Nominal pipe diameterDi = Effective internal diameter of pipeFor the continuous pressure drop in the cone, consider an equivalent length of pipe of diameter DN1= L PRESSURE DROPS DUE TO SUDDEN ENLARGEMENT IN WATER COLUMN METRES PRESSURE DROPS DUE TO SUDDEN RESTRICTION IN WATER COLUMN METRES PRESSURE DROPS LOCALISED TO DIVERGENT ISO CONES…

  • ISO 9906: How to Select Efficient Pumps

    The specifications given herein refer to the curves given in our catalogues and Data Books (see www.ebaraeurope.com). All performance curves have been calculated in compliance with ISO 9906 Annex A. Tolerances per ISO 9906 Annex A. The curves refer to the effective speed of the asynchronous motors at 50 Hz. The measurements were run at…

  • Pressure Tank Essentials: Membrane vs Air Cushion Autoclaves

    SELECTION AND SIZING OF THE AUTOCLAVE The supply pressure tank, or autoclave, is used to limit the number of pump starts per hour by supply part of its water reserve to the circuit, which is kept pressurised by the air above it. The autoclave may be of the air cushion or membrane type. In the…

  • Pressure Drop and Fluid Dynamics in Pipes

    This is the resistance opposed to the flow of the fluid by the walls of a pipe or by variations of diameter of the pipe, or at intersections with bends and valves in the circuit. It is also determined by the fluid temperature and geodetic height of the installation. It is generally expressed in watercolumn…

  • What is Pump Total Head? Key Factors in Fluid Mechanics

    Determination of the HEAD (H) The head is the maximum total difference in level which a pump can elevate a fluid. The head includes the level difference between the pump and the supply tank, if located at a lower level, and the difference between the pumpand the destination tank at a higher level. The route…

  • Understanding IP Protection Ratings for Electrical Equipment

    PROTECTION RATING This is identified as IP (Ingress Protection – the degree of protection against the ingress of foreign materials and agents). CEI EN 60529 (protection rating of housings – IP code) establishes the IP rating to indicate the protection of electrical equipment against access to live components and against penetration by water and foreign…

  • Understanding Direct and Star-Delta Motor Starting Techniques

    Direct start Direct starting is the simplest method of starting and is obtained by connecting the motor’s rated voltage to the stator. In general, this is used for small motors which can run up to speed in short time.Fig. 1 shows the direct starting procedure, obtained by closingconnections “1”. The main disadvantages, as can be…

  • Understanding Fluid Flow Rate (Q) for Efficient Water Supply

    Determining the FLOW RATE (Q)The quantity of fluid that passes through a section of area “A” in unit time. The first value to calculate when sizing a pressurisation unit is the total quantity of water it must supply to satisfy the maximum theoretical demand, given by the sum of the water demand at each point…

  • PUMP SUCTION HEAD

    NPSH (Net Positive Suction Head) A pump installed above the water level can suck the water due to theatmospheric pressure on the surface itself, which is equivalent to about 10 m of water column. This means that, however great the suction power of the pump, the height from which it can draw up the fluid…

  • INSTRUCTION MANUAL EBARA Self Priming Pumps SQPB

    INSTALLATION Location(1) This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install in a well-ventilated area with low humidity. Ambient temperature should be 40o C or less.(3) Install where inspection and maintenance procedures can be…

  • Ebara Europe motor INSTRUCTION MANUAL REGARDING USE AND MAINTENANCE

    NEVER ALLOW THE MOTOR-DRIVEN PUMP TO OPERATE WITHOUTWATER. DOING SO CAN SERIOUSLY DAMAGE THE INTERNAL COMPONENTS. GENERAL WARNINGSa) Our surface pumps are designed to operate at a temperature no higher than40°C and a level no higher than 1000 metres;b) our motor-driven pumps cannot be used in swimming pools or similar plants; c) prolonged motor pump…

  • Aqua System Pressure Tank / Expansion tank

    INSTALLATION AND OPERATING INSTRUCTIONS Before turning on the vessel supply, check that it is correctly installed, fill it switching on the pump until the pressure switch turns it off automatically. Turn on and off repeatedly the farest tap in order to exhaust the air bubbles inside the pipes. After this turn on one or more…